1.
Korean Journal of Radiology ; : 416-422, 2013.
Article in English | WPRIM | ID: wpr-218259

ABSTRACT

OBJECTIVE: An ex vivo study found a copper-containing intrauterine device (IUD) to be safe for women undergoing an MRI examination at a 3.0-T field. No significant artifacts caused by the metallic implant were detected. However, there are still no in vivo data about these concerns. The aim of this study was to evaluate 3.0-T magnetic field interactions of copper-containing IUDs in vivo. MATERIALS AND METHODS: Magnetic field interactions and potential adverse events were evaluated in 33 women using a questionnaire-based telephone survey. Two experienced radiologists performed artifact evaluation on MR images of the pelvis. RESULTS: Eighteen patients were eligible for the survey. One patient reported a dislocation of the IUD after the MR examination. All other patients had no signs of field interactions. No IUD-related artifacts were found. CONCLUSION: MRI at 3.0-T is possible for women with copper-containing IUDs. However, consulting a gynecologist to check the correct position of the IUD and exclude complications after an MR examination is highly recommended. High-quality clinical imaging of the female pelvis can be performed without a loss in image quality.


Subject(s)
Adult , Female , Humans , Middle Aged , Artifacts , Copper , Hot Temperature , Intrauterine Devices, Copper/adverse effects , Magnetic Fields , Magnetic Resonance Imaging/adverse effects , Pelvis
SELECTION OF CITATIONS
SEARCH DETAIL